The orifice flow equation gives the flow through a plate with a hole in a pipe from the measured differential pressure: Q = Cd × A₂ × √(2ΔP / (ρ(1 − β⁴))), where Cd is the discharge coefficient (about 0.6 to 0.63 for a sharp-edged plate), A₂ the bore area, ρ the fluid density and β the ratio of bore to pipe diameter. Flow rises with the square root of differential pressure. Example: a 2 in bore in 4 in Schedule 40 pipe (β ≈ 0.50) with a 5 psi drop passes about 168 gpm of water.
How an Orifice Plate Works
Wikipedia explains that as fluid approaches the plate its pressure builds slightly, then as it converges through the hole its velocity increases and pressure falls. Just downstream, at the vena contracta, velocity is highest and pressure lowest; beyond that the flow expands and pressure partly recovers. Measuring the pressure difference between taps upstream and downstream gives the flow rate.
The Orifice Equation Explained
| Symbol | Meaning | Notes |
|---|---|---|
| Q | Volumetric flow rate | m³/s in SI |
| Cd | Discharge coefficient | Corrects for the vena contracta and losses; ≈ 0.6–0.63 for sharp-edged plates |
| A₂ | Orifice bore area, πd²/4 | d = bore diameter |
| ΔP | Differential pressure, p₁ − p₂ | Between the standard tap locations |
| ρ | Fluid density | Upstream density for gases |
| β | d / D | D = pipe inside diameter |
| 1/√(1 − β⁴) | Velocity of approach factor | C = Cd × this factor is the flow coefficient |
Wikipedia notes the basic derivation uses the orifice area rather than the smaller vena contracta, and ignores friction, viscosity and turbulence, which is why the discharge coefficient is introduced. For sharp-edged plates with standard tappings (corner, flange or D and D/2), coefficients are around 0.6 to 0.63; conical-entrance plates are about 0.73 and quarter-circle plates 0.77 to 0.85. ISO 5167 and ASME MFC-3M use the Reader-Harris/Gallagher equation to calculate Cd precisely.
Orifice Flow Calculator
Worked example
A sharp-edged orifice with a 2.000 in bore in 4 in Schedule 40 pipe (4.026 in ID) gives β = 0.497. With water (SG 1.0), a 5 psi differential and Cd = 0.61, the equation gives about 168 gpm. Quadrupling the differential to 20 psi doubles the flow to about 336 gpm.
Compressible Flow (Gases and Steam)
Wikipedia notes the basic equation applies only to incompressible flow. For gases, an expansibility factor ε is added: qm = C ε A₂ √(2ρ₁(p₁ − p₂)), with ε = 1 for liquids and calculated from empirical formulas for gases. For small β, such as restriction orifices and tank discharges, the flow may approach choked conditions, though real gases through thin-plate orifices never become fully choked. For flow through valves, see valve flow coefficient Cv.
Installation and Accuracy
- Straight pipe: a fully developed profile needs about 20 to 40 diameters upstream, or a flow conditioner (Wikipedia).
- Plate orientation: the sharp edge faces upstream; standards require the upstream face to be flat and smooth.
- Beta ratio: stay within the limits of the standard you are using, or the published coefficients do not apply.
- Permanent loss: orifices recover pressure less well than venturis or nozzles, so part of the ΔP becomes pumping energy.
- Square-root extraction: a DP transmitter output must be square-rooted to read flow; low flows give very small ΔP and poor accuracy.
For converting differential pressure to head, see psi to feet of head; for pipe friction losses, the Colebrook equation.
Frequently Asked Questions
What is the orifice flow equation?
For an incompressible fluid, Q = Cd × A₂ × √(2ΔP / (ρ(1 − β⁴))), where Cd is the discharge coefficient, A₂ the bore area, ΔP the differential pressure, ρ the density and β the bore-to-pipe diameter ratio.
What is the discharge coefficient of an orifice?
The ratio of actual to theoretical flow, accounting for the vena contracta and losses. Wikipedia notes sharp-edged orifice plates have coefficients around 0.6 to 0.63; conical entrance plates about 0.73 and quarter-circle plates 0.77 to 0.85.
What is the beta ratio?
β = orifice bore diameter ÷ pipe inside diameter. The term 1/√(1 − β⁴) is the velocity of approach factor.
What is the flow coefficient C?
Cd multiplied by the velocity of approach factor 1/√(1 − β⁴). Wikipedia notes that for rough approximations it can be taken as 0.60 to 0.75.
How does flow change with pressure drop?
Flow is proportional to the square root of differential pressure: four times the ΔP gives twice the flow. That square-root relationship is why DP flow transmitters apply a square-root extraction.
What is the vena contracta?
The point just downstream of the orifice where the jet is narrowest, velocity highest and pressure lowest.
How much straight pipe does an orifice need?
Wikipedia notes an orifice needs a fully developed flow profile, typically 20 to 40 pipe diameters upstream depending on Reynolds number, or a flow conditioner.
Does an orifice plate cause permanent pressure loss?
Yes. Orifice plates do not recover pressure as well as venturis or nozzles, so part of the differential is lost permanently, which costs pumping energy.
How is the orifice equation used for gases?
An expansibility factor ε is added: qm = C ε A₂ √(2ρ₁(p₁ − p₂)). At small β and high pressure ratios the flow may approach choked conditions.
What standards cover orifice plates?
ISO 5167 and ASME MFC-3M; Wikipedia notes they align closely and use the same Reader-Harris/Gallagher equation for the discharge coefficient of sharp-edged plates.
Sources and Further Reading
- Wikipedia: Orifice plate: operation, equations, discharge coefficients, compressible flow and installation.
- Engineering ToolBox: Orifice, nozzle and venturi flow rate meters: flow meter equations.
- Wikipedia: Discharge coefficient: definition.