In GD&T, flatness controls only the form of a planar surface: it must lie between two parallel planes at any angle, with no datum. Parallelism adds orientation: the two planes must be parallel to a datum. Profile of a surface is the catch-all: a band around the true shape. Without datums it controls form, and with datums it can also control orientation, location and size. Parallelism also limits flatness, and both must be tighter than the size tolerance to add anything.
Flatness vs Parallelism vs Profile
| Flatness ⏥ | Parallelism ∥ | Profile of a surface ⌓ | |
|---|---|---|---|
| Category (ASME Y14.5) | Form | Orientation | Profile |
| Datum | Never | Required | Optional |
| Tolerance zone | Two parallel planes, any angle | Two planes parallel to the datum (or a cylinder for an axis) | Two surfaces following the true profile |
| Applies to | Planar surfaces (or a derived median plane) | Surfaces, axes, median planes | Any surface shape |
| Controls | Form | Orientation (and form) — not location | Form; with datums also orientation, location, size |
| Typical check | Indicator with surface leveled, or CMM | Datum on surface plate, indicator TIR | CMM against the CAD model |
Flatness
GD&T Basics describes flatness as the most common way to control the form of a planar surface, regardless of any datums or other features. The zone is two parallel planes within which the whole surface must lie, unconstrained to anything else. It is often used to qualify a primary datum surface or to control sealing faces. Wikipedia notes flatness is critical where parts must seal air- or liquid-tight across a surface, and that surfaces flat to about one helium light band will wring together, as gauge blocks do.
Because of Rule #1 (perfect form at maximum material condition), the size tolerance already limits flatness on a part with plus-minus size limits. A flatness callout is useful only as a refinement, tighter than the size tolerance, unless the independency symbol is applied.
Parallelism
Parallelism requires a surface (or an axis or midplane) to be parallel to a datum. For a surface the zone is two parallel planes oriented at 0° to the datum, and the value is a width in mm or inches, not an angle. Parallelism does not control location. If the feature must also be located, position or profile with datums does both (GD&T Basics). To inspect it, set the datum on a granite surface plate and sweep an indicator across the surface; the total indicator reading is the parallelism error.
Profile of a Surface and Profile of a Line
Profile of a surface defines a 3D zone of two surfaces that follow the designed contour across the whole surface. Profile of a line applies the same idea to individual cross-sections (GD&T Basics). Wikipedia notes that profile tolerances are equal bilateral unless otherwise specified. ASME Y14.5-2009 added the unequally disposed symbol for zones shifted toward plus or minus material.
- Without datums, profile acts as a form control, like a general version of flatness or cylindricity.
- With datums, profile can mimic perpendicularity, parallelism or angularity, and can also control location and size: every aspect of a surface.
- Profile of a line inside profile of a surface: a tighter line control keeps each cross-section smooth while the looser surface control sets overall position.
Flatness and Parallelism Calculator
The sample readings range from 0 to 0.0014, so parallelism to datum A is 0.0014. Fitting a plane removes the tilt, leaving a flatness of 0.0004. Here the surface is flat within 0.001 but tilted. It passes a 0.002 parallelism callout but would fail 0.001. Wikipedia’s flatness article notes that flatness can be evaluated by least squares or by the minimum zone (worst case) between two parallel planes.
Reading the Feature Control Frame
Geometric tolerances are given in feature control frames: rectangular boxes with the symbol, the tolerance value, any modifiers and the datum references (Wikipedia). For example, “⏥ | 0.05” is flatness within 0.05 with no datum. “∥ | 0.1 | A” is parallelism within 0.1 to datum A. “⌓ | 0.2 | A | B | C” is profile of a surface within a 0.2 band, located and oriented from datums A, B and C. Drawing views follow the projection method in the title block; see first-angle vs third-angle projection.
For round features, see concentricity vs runout.
Frequently Asked Questions
What is profile tolerance in GD&T?
A tolerance that defines a band around the true (basic) shape of a line or surface. Profile of a surface is a 3D zone of two surfaces offset from the true profile; every point must fall inside it. It can be used with datums (controlling location and orientation too) or without (form only).
What is the difference between flatness and parallelism?
Flatness is a form control: the surface must lie between two parallel planes that can sit at any angle, with no datum. Parallelism is an orientation control: the two planes must be parallel to a datum, so it limits tilt as well as flatness.
Does parallelism control flatness?
Yes, indirectly. A surface inside a parallelism zone is also flat to at least that value, which is why a separate flatness callout is only useful when it is tighter (a refinement).
What is the difference between profile and flatness?
Flatness applies only to planar surfaces and never uses a datum. Profile of a surface works on any shape; without datums it acts as a form control like flatness, and with datums it can also control orientation, location and size.
How do I control coplanarity in GD&T?
Use profile of a surface across the surfaces, connected or noted with the number of surfaces, without a datum. Separate flatness callouts on each surface only make each one flat to itself, not to each other (GD&T Basics).
What is the parallelism symbol?
Two parallel slanted lines (∥, Unicode U+2225) in the feature control frame, followed by the tolerance value and the datum letter.
What is the flatness symbol?
A parallelogram (⏥, U+23E5). It is never followed by a datum reference.
Is profile tolerance bilateral?
By default, yes: profile tolerances are equal bilateral about the true profile unless otherwise specified. The unequally disposed symbol (U, added in ASME Y14.5-2009) shifts the zone toward plus or minus material.
How is parallelism measured?
Put the datum surface on a granite surface plate and run an indicator across the controlled surface; the total indicator reading is the parallelism error (GD&T Basics).
Is flatness the same as surface finish?
No. Flatness limits the overall form of the surface over its area; surface finish (roughness) describes fine texture over short lengths and is specified separately with surface texture symbols.
Sources and Further Reading
- Wikipedia: Geometric dimensioning and tolerancing: ASME Y14.5 rules, symbol table, feature control frames, bilateral profile.
- Wikipedia: Flatness (manufacturing): definition, least-squares vs minimum-zone evaluation.
- GD&T Basics: Flatness: zone, Rule #1, refinement, coplanarity.
- GD&T Basics: Parallelism: zones and inspection.
- GD&T Basics: Profile of a Surface: 3D zone, with and without datums.