Relay Coil Protection: Selecting a Diode, TVS or Resistor Snubber

By editor Updated 7 min read
Relay coil with four suppressor symbols, a diode, a zener pair, a TVS and a resistor, showing a voltage spike being clamped

Use a diode in series with a zener, or a bidirectional TVS diode, across a DC relay coil when the normally-open contacts switch a real load. A plain flyback diode protects the switch but slows the relay’s release so much that contacts can weld. For AC coils, use an RC suppressor or a varistor instead. TE Connectivity’s application notes are the clearest source on this, and they recommend testing the relay with the exact suppressor you will use.

MethodCoil typeRelease speedPeak voltageBest use
Rectifier diode aloneDCSlowestAbout 0.7 VNC-contact loads, or light loads only
Diode + zenerDC (polarised)Near optimumZener + diode dropPLC and transistor-driven relays
Bidirectional TVSDC (non-polarised)Least effectTVS clamp voltageBest for NO contact life (TE)
MOV (varistor)AC or DCSmall effectHigher than a TVSLow cost, non-polarised
ResistorDCDepends on valueR × coil currentSockets, where power loss is acceptable
RC snubberACModerateUp to 300% of nominal (Schneider)AC contactor coils
From TE Connectivity application notes and Schneider Electric FAQ FA102916.
1,000–1,500 V
turn-off spike from a 12 V relay (TE)
0.7 V
clamp with a plain diode, the slowest release
1.1–1.5×
drop-out time with a varistor (Schneider)
1.2–2×
drop-out time with an RC unit (Schneider)

Why Relay Coils Need Suppression

When current through a coil is interrupted, its collapsing magnetic field tries to keep the current flowing and produces a high voltage spike. TE says a 12 V DC relay may generate 1,000 to 1,500 V during turn-off, and that this spike plus the supply voltage appears across whatever switched the coil off. That is enough to destroy a transistor, damage a PLC output or cause electrical noise. For how PLCs drive relays, see what is a PLC. For PLC output protection in general, see our PLC I/O fuse protection guide.

Suppression Methods Compared

Relay coil suppression methodsFour DC relay coil suppression circuits: a diode alone, a diode in series with a zener, a bidirectional transient voltage suppressor, and a resistor, each placed in parallel with the coil.Four ways to suppress a DC relay coilDiode onlyCoilSlowest releaseTE: avoid on NO loadsDiode + zenerCoilFast release, polarisedTE: best if polarisedBidirectional TVSCoilFast release, non-polarisedTE: best for NO contactsResistorCoilSimple, costs powerR = Vpeak ÷ IcoilIndustrialBasicsindustrialbasics.com
Figure 1: Summary of two TE Connectivity application notes on relay coil suppression.

TE lists the options for a suppressor placed in parallel with the coil, which it prefers because it sits closest to the relay. In parallel with the switch, a zener diode or RC snubber can be used instead.

Diode only (flyback diode)

A reverse-biased rectifier across the coil limits the spike to about one diode drop, which gives the switch maximum protection. TE calls this “cost effective” but warns that its impact on relay performance “can be devastating”, leading to unexplained, random tack welding of contacts. The diode keeps current circulating in the coil, so the magnetic field decays slowly and holds the armature back.

Diode plus zener

A rectifier in series with a zener lets the coil voltage rise to the zener voltage before current flows, so the stored energy is dumped quickly. TE says the impact on release dynamics is minimal, calls it normally a low-cost method, and suggests it from the standpoint of physics for optimum release and NO contact life. The only design precautions are a suitable breakdown voltage and enough impulse power rating.

Transient voltage suppressor (TVS) diode

For normally-open contact life, TE says the best method is a silicon transient suppressor diode, because it lets the transient rise to a set level and then conducts with low impedance. A bidirectional TVS keeps the relay non-polarised. A unidirectional one needs a series rectifier and then has little advantage over a zener.

MOV and resistor

An MOV acts like a TVS but clamps higher. TE’s example compares a 33 V TVS clamping at 30 to 36 V with a 33 V MOV clamping at 45 to 55 V. A resistor across the coil is often the cheapest option where its heat can be tolerated. TE gives a starting value of R = Vpeak ÷ Icoil, where Vpeak is the transient voltage you can permit, and advises consulting the relay maker. TE now calls the RC snubber the least economical choice for DC coils. If you do use one, our guide to capacitor codes such as 104 helps read the part markings.

Why a Plain Diode Can Weld Contacts

Coil current decay with different suppressorsWith a diode alone the coil current decays slowly, so the armature is held longer. With a diode and zener or a TVS, the current falls quickly and the contacts open with more speed.Why a plain diode slows the relay (illustrative)Time after the switch opensCoil currentDiode only: slow decayDiode + zener or TVS: fastLevel where springs win and contacts openIndustrialBasicsindustrialbasics.com
Figure 2: Shape only, not measured data. TE explains that slow flux decay reduces the force that breaks contact welds.

TE explains the mechanism. When power relay contacts close onto a fast-rising or high inrush load, a minute molten interface forms and leaves a micro-weld. On the next opening, the armature’s speed and momentum normally break it. With a plain diode, the slowly decaying flux reduces the net opening force, so the armature can slow, stop or even briefly reverse. Without enough momentum, the micro-weld holds and the contacts stay closed.

This matters most in PLC panels where a transistor output drives an interposing relay that switches a solenoid, lamp or contactor. See also contactor vs relay and dry contact relays.

Zener and Resistor Calculator

DC Relay Coil Suppressor Calculator
IndustrialBasics estimate. Assumes a 0.7 V rectifier drop. Check the zener or TVS energy rating and test the relay with the suppressor you will use, as TE recommends.

The calculator applies the rule TE describes: the zener voltage limits the switch voltage to a level within its rating. Supply plus zener plus the rectifier drop must stay under the switch rating after your margin. The resistor value uses TE’s R = Vpeak ÷ Icoil, taking the permitted peak as the allowed switch voltage minus the supply.

Worked Example: 24 V Relay on a PLC Transistor Output

StepValue
Coil24 V DC, 1,440 Ω, so 16.7 mA
Output transistor rating60 V (example)
Allowed with 20% margin48 V
Maximum zener voltage48 − 24 − 0.7 = 23.3 V, so use a standard value at or below this
Resistor alternative24 V ÷ 0.0167 A = about 1,440 Ω, dissipating 0.4 W
An illustrative example. Use your PLC output’s actual voltage rating and the relay’s coil data.

Note how the resistor option dissipates as much power as the coil itself while the relay is on. That is why TE limits it to cases where the heat can be tolerated.

AC Coils: RC or Varistor

Diodes cannot be used on AC coils. Schneider’s guidance for its contactor suppressors is clear:

PointRC suppressorVaristor
Coil typeAC onlyAC or DC
Drop-out time1.2 to 2 times normal1.1 to 1.5 times normal
Transient limit300% of nominal voltage max200% of nominal voltage max
From Schneider Electric FAQ FA102916.
Before you finalise: Whatever you fit, test it. TE notes it is normal industry practice to rate relays without coil suppression, so evaluate the relay with the suppression that will actually be used.

For freewheeling diodes on motors, solenoids and PWM drives, and how to estimate decay time, see our freewheeling diode guide.

Frequently Asked Questions

Why do relay coils need a snubber or diode?

Switching off a coil makes its magnetic field collapse, which generates a large voltage spike. TE notes that a 12 V DC relay may generate 1,000 to 1,500 V at turn-off, enough to damage transistors and PLC outputs.

Is a flyback diode bad for relays?

It protects the switch fully, but TE warns it slows the release so much that normally-open contacts can “tack weld” on inductive or high inrush loads. Use a diode plus zener or a TVS when the NO contacts carry the main load.

What is the best relay coil suppression?

For normally-open contact life, TE recommends a silicon transient suppressor diode, or a rectifier diode in series with a zener when the relay can be polarised.

How do I choose the zener voltage?

Pick it so that supply voltage plus zener voltage plus the diode drop stays below the switch’s voltage rating, with margin. Also check its impulse power rating.

Can I use a diode on an AC relay or contactor coil?

No. A diode would conduct on every half cycle. Schneider uses RC suppressors for AC coils only and varistors for AC or DC coils.

RC suppressor or varistor?

Schneider says RC units increase drop-out time to 1.2 to 2 times normal and limit transients to 300% of nominal, while varistors give 1.1 to 1.5 times and 200%.

Is an MOV as good as a TVS diode?

Similar, but TE says an MOV clamps higher. Its example: a 33 V TVS clamps at 30 to 36 V, while a 33 V MOV clamps at about 45 to 55 V.

When is a plain diode the right choice?

TE notes that when the main load is on the normally-closed contacts, the slower armature reduces bounce on closing, so a diode alone may help.

Sources and Further Reading

About the author