The Hazen-Williams equation estimates friction head loss for water flowing full in a pipe from the flow rate, the inside diameter and a roughness coefficient C. In US units, head loss per 100 ft = 0.2083 × (100/C)1.852 × Q1.852 / d4.8655, with Q in gpm and d in inches. For example, 200 gpm in a 3.048 in polyethylene pipe (C = 140) loses about 9 ft of head per 100 ft (Engineering ToolBox). The equation is valid for water only, at about 40–75 °F in turbulent flow.
Hazen-Williams Formula
Wikipedia gives the general form, where V is mean velocity, R is hydraulic radius (d/4 for a full pipe) and S is the slope of the energy line, or head loss per unit length. Hazen and Williams adjusted the exponents of the older Chézy formula so that C stays nearly constant over a wide range of conditions. Unlike the Darcy friction factor, C does not depend on the Reynolds number, so no iteration is needed. Solving the general form for head loss in a full circular pipe gives the forms used every day.
| Form | Equation | Units |
|---|---|---|
| US head loss (Engineering ToolBox) | h100ft = 0.2083 (100/C)1.852 Q1.852 / d4.8655 | ft of water per 100 ft; Q gpm; d in |
| US pressure loss (NFPA sprinkler form) | P/L = 4.52 Q1.852 / (C1.852 d4.87) | psi per ft; Q gpm; d in |
| US slope, feet units | S = hf/L = 4.73 Q1.852 / (C1.852 d4.87) | ft per ft; Q cfs; d ft |
| SI head loss | hf = 10.67 L Q1.852 / (C1.852 d4.8704) | m; Q m³/s; d m; L m |
| Velocity (US) | v = 0.408709 Q / d² | ft/s; Q gpm; d in |
Worked Example
Engineering ToolBox works an example: 200 gpm of water through a 3 in PEH DR 15 pipe with an inside diameter of 3.048 in, C = 140, length 30 ft. Head loss per 100 ft = 0.2083 × (100/140)1.852 × 2001.852 / 3.0484.8655 ≈ 9.0 ft of water. Over 30 ft that is about 2.7 ft. The NFPA form gives 3.84 psi per 100 ft, which agrees to within about 2% once converted to head. Velocity is 8.8 ft/s.
Hazen-Williams C Factor Table
| Pipe material | C factor |
|---|---|
| PVC, CPVC | 150 |
| Fiberglass (FRP) | 150 |
| Polyethylene (PE, PEH) | 140 |
| Copper | 130–140 |
| Ductile iron (DIP) | 140 |
| Cast iron, cement lined | 140 |
| Steel, new unlined | 140–150 |
| Cast iron, new unlined | 130 |
| Galvanized iron | 120 |
| Concrete | 100–140 |
| Cast iron, 10 years old | 107–113 |
| Cast iron, 20 years old | 89–100 |
| Steel, welded and seamless | 100 |
| Cast iron, 30 years old | 75–90 |
| Cast iron, 40 years old | 64–83 |
| Corrugated steel or metal | 60 |
C drops as pipes age, scale and corrode. Cast iron falls from 130 new to 107–113 after 10 years, 89–100 after 20 and 64–83 after 40 years. For a system expected to run for decades, design with an aged value rather than the new-pipe figure.
Hazen-Williams Calculator
Limitations
- Water only. Use Darcy-Weisbach for oils, chemicals, slurries, steam or gases.
- Temperature: about 40–75 °F (5–25 °C), kinematic viscosity about 1.1 cSt. Engineering ToolBox notes that hot water, for example 0.55 cSt at 130 °F, gives significant error.
- Turbulent flow: Reynolds number above about 105.
- Normal velocity: C values are based on about 3 ft/s (1 m/s) flow.
- Empirical: no theoretical basis, so it should not be pushed far outside the conditions it was fitted to.
Frequently Asked Questions
What is the Hazen-Williams equation?
An empirical formula, published by Allen Hazen and Gardner Williams in 1906, that relates water flow in a pipe to the pipe size, its roughness coefficient C and the friction head loss (Wikipedia). It is used for water mains, fire sprinklers and irrigation.
What is the Hazen-Williams formula in US units?
For head loss: h per 100 ft = 0.2083 × (100/C)^1.852 × Q^1.852 / d^4.8655, with Q in gpm and d in inches (Engineering ToolBox). For pressure, the NFPA sprinkler form is P/L = 4.52 Q^1.852 / (C^1.852 d^4.87) in psi per foot.
What is the Hazen-Williams formula in SI units?
hf = 10.67 × L × Q^1.852 / (C^1.852 × d^4.8704), with L and d in meters and Q in m³/s (Wikipedia).
What is the Hazen-Williams C factor?
A roughness coefficient: the higher the number, the smoother the pipe. PVC is 150, polyethylene and ductile iron 140, new cast iron 130, galvanized iron 120, and old cast iron falls to 64–83 at 40 years (Engineering ToolBox).
What C value should I use for steel pipe?
Engineering ToolBox lists new unlined steel at 140–150 and welded and seamless steel at 100. Wikipedia’s design table gives 90–120 for steel, allowing for roughness increasing with age. Many designers use the lower, aged value.
Can Hazen-Williams be used for fluids other than water?
No. It is only valid for water at roughly room temperature (about 40–75 °F) in turbulent flow. Use the Darcy-Weisbach equation for other liquids, gases or hot water (Engineering ToolBox, Wikipedia).
Hazen-Williams vs Darcy-Weisbach: which is better?
Darcy-Weisbach with the Moody diagram is the more accurate and general method. Hazen-Williams is simpler because C does not depend on the Reynolds number, which is why water and sprinkler work still uses it (Engineering ToolBox, Wikipedia).
Why is the exponent 1.852?
It comes from raising the general form V = k·C·R^0.63·S^0.54 to the power 1/0.54 to solve for head loss. Friction loss therefore rises with flow to the 1.852 power, and falls with diameter to about the 4.87 power.
How much does doubling pipe diameter reduce friction loss?
Roughly by a factor of 2^4.87, about 29 times, for the same flow. Going up one pipe size often solves a friction-loss problem.
Does Hazen-Williams include fittings and valves?
No. It gives friction loss in straight pipe only. Add minor losses for elbows, tees, valves and meters separately, often as equivalent lengths of pipe.
Sources and Further Reading
- Wikipedia: Hazen–Williams equation: general form, pipe equations in US and SI units, design C factors.
- Engineering ToolBox: Hazen-Williams water flow formula: head loss form, worked example, limitations.
- Engineering ToolBox: Hazen-Williams coefficients: C factors by pipe material.