To convert psi to feet of head, multiply by 2.31 and divide by the liquid’s specific gravity (SG). To convert feet of head to psi, multiply by 0.433 and by SG. For water (SG 1.0), 1 psi = 2.31 ft of head and 1 ft of head = 0.433 psi, so 100 psi = 231 ft and 120 ft = 52 psi. Lighter liquids such as gasoline need more feet of head to make the same pressure; heavier ones such as glycol need less.
PSI to Feet of Head Formula
Engineering ToolBox gives the two pump-curve conversions as h = 2.31 p ÷ SG and p = 0.433 h SG, where h is head in feet, p is pressure in psi and SG is the specific gravity of the fluid. Wilo’s pump engineering handbook lists the same pair: 1 psi = 2.31 ft of water and 1 ft of water = 0.433 psi.
Where 2.31 comes from: NIST SP 811 lists 1 psi as 6,894.757 Pa and one conventional foot of water as 2,989.067 Pa, so 1 psi supports 6,894.757 ÷ 2,989.067 = 2.3067 ft of water at its densest. At 60 °F water is 0.1% lighter, which rounds to the familiar 2.31.
Worked examples
- 40 psi to feet of head (water): 40 × 2.31 = 92.4 ft.
- 150 ft of head to psi (water): 150 × 0.433 = 65.0 psi.
- 60 psi of diesel-type fuel oil (SG 0.893): 60 × 2.31 ÷ 0.893 = 155 ft.
- 80 ft of sea water (SG 1.028) to psi: 80 × 0.433 × 1.028 = 35.6 psi.
PSI to Feet of Head Calculator
PSI to Feet of Head Chart (Water)
| psi | ft of head | psi | ft of head |
|---|---|---|---|
| 1 psi | 2.3 ft | 60 psi | 138.5 ft |
| 2 psi | 4.6 ft | 70 psi | 161.6 ft |
| 5 psi | 11.5 ft | 80 psi | 184.7 ft |
| 10 psi | 23.1 ft | 90 psi | 207.8 ft |
| 15 psi | 34.6 ft | 100 psi | 230.9 ft |
| 20 psi | 46.2 ft | 125 psi | 288.6 ft |
| 25 psi | 57.7 ft | 150 psi | 346.3 ft |
| 30 psi | 69.3 ft | 200 psi | 461.7 ft |
| 40 psi | 92.3 ft | 250 psi | 577.2 ft |
| 43.3 psi | 100.0 ft | 300 psi | 692.6 ft |
| 50 psi | 115.4 ft | 500 psi | 1154.4 ft |
Feet of Head to PSI Chart (Water)
| ft of head | psi | ft of head | psi |
|---|---|---|---|
| 1 ft | 0.43 psi | 75 ft | 32.49 psi |
| 2 ft | 0.87 psi | 80 ft | 34.65 psi |
| 5 ft | 2.17 psi | 100 ft | 43.31 psi |
| 10 ft | 4.33 psi | 120 ft | 51.98 psi |
| 20 ft | 8.66 psi | 150 ft | 64.97 psi |
| 23.1 ft | 10.01 psi | 200 ft | 86.63 psi |
| 25 ft | 10.83 psi | 231 ft | 100.05 psi |
| 30 ft | 12.99 psi | 250 ft | 108.28 psi |
| 40 ft | 17.33 psi | 300 ft | 129.94 psi |
| 50 ft | 21.66 psi | 400 ft | 173.25 psi |
| 60 ft | 25.99 psi | 500 ft | 216.57 psi |
Why Specific Gravity Matters
Specific gravity is the ratio of a liquid’s density to the density of water at 4 °C (39.2 °F), the definition Engineering ToolBox uses. A column of a lighter liquid weighs less, so it must be taller to press down with the same psi.
| Liquid | Specific gravity | ft of head per psi | psi per ft of head |
|---|---|---|---|
| Water, 60 °F (15 °C) | 0.9991 | 2.31 | 0.433 |
| Water, 140 °F (60 °C) | 0.9832 | 2.35 | 0.426 |
| Water, 212 °F (100 °C) | 0.95835 | 2.41 | 0.415 |
| Sea water | 1.028 | 2.24 | 0.446 |
| Ethylene glycol | 1.1 | 2.10 | 0.477 |
| Fuel oil | 0.893 | 2.58 | 0.387 |
| Kerosene | 0.82 | 2.81 | 0.355 |
| Gasoline (vehicle) | 0.739 | 3.12 | 0.320 |
This is why Engineering ToolBox notes that pump curves are drawn in feet or meters of head. A pump that develops 231 ft of head makes 100 psi on cold water but only about 74 psi on gasoline (231 × 0.433 × 0.739), even though the impeller is doing the same job.
Converting Pump Gauge Readings to Total Head
Field technicians often check a pump against its curve with a suction and a discharge gauge. The pressure the pump adds, converted to feet, plus the height between the two gauges, gives the total head it is developing:
- Read both gauges in the same units. A suction gauge below atmospheric reads in inHg vacuum; convert it to a negative psig first (1 inHg = 0.491 psi).
- Subtract suction from discharge to get the pressure the pump adds.
- Convert to feet with × 2.31 ÷ SG.
- Add the height difference between the gauge centers (Δz), positive if the discharge gauge is higher.
- Add the velocity-head difference if the suction and discharge pipes differ in size. Wilo gives velocity head as v² ÷ 64.4, with v in ft/s.
With 5 psig suction, 65 psig discharge and 2 ft between gauges on cold water, the pump develops (65 − 5) × 2.31 + 2 = 141 ft. Find that head on the curve to read the flow the pump should be delivering. If it does not match, the impeller may be worn, the pump may be running backward, or the gauges may be wrong.
From feet of head to pump power
Head also sets how much power the liquid receives. Wilo’s formula sheet gives water horsepower = gpm × head (ft) × SG ÷ 3,960; dividing by pump efficiency gives the shaft power the motor must supply. 200 gpm at 135 ft of water is 200 × 135 ÷ 3,960 = 6.8 water hp. To express that in kilowatts, see our kW to hp conversion.
Static Head, Pressure Head and Velocity Head
| Term | What it means | Typical use |
|---|---|---|
| Static head (elevation head) | Height of the liquid surface above the point of interest | Tank level, water tower pressure, lift from sump to roof |
| Pressure head | Pressure expressed as a height of liquid: p ÷ (ρg) | Converting gauge psi to feet on a pump curve |
| Velocity head | Kinetic energy as a height: v² ÷ 2g (v² ÷ 64.4 in ft/s) | Correcting gauge readings where pipe sizes change |
| Friction head | Energy lost to friction in pipe, valves and fittings | System curve and pump selection |
| Total dynamic head (TDH) | Static + friction + velocity head the pump must supply | Reading flow off a pump curve |
Wikipedia’s hydraulic head article also notes that pressure head depends on the density of the liquid, which changes with temperature and salinity, so measurements are standardized to fresh water when they need to be compared. That is the same reason the calculator above lets you pick hot water or sea water.
Using Head to Measure Tank Level
The relationship works in reverse for level measurement. A pressure transmitter at the bottom of an open tank reads the head of liquid above it, so level (ft) = psi × 2.31 ÷ SG. A gauge transmitter reading 8.66 psi under water means about 20 ft of level; if the tank holds glycol at SG 1.10, the same reading means only about 18.2 ft.
Use a gauge (vented) transmitter on open tanks so atmospheric changes cancel out, and set the SG in the transmitter or PLC scaling. Our psig vs psia guide explains vented versus absolute sensors, and types of industrial sensors covers other level technologies.
Common Mistakes
- Leaving out specific gravity. 2.31 is only right for water.
- Dividing when you should multiply. Head in feet is always the bigger number for water: 1 psi is 2.31 ft, not 0.433 ft.
- Mixing gauge and absolute values. Convert both gauges on the same basis, and convert vacuum readings to negative psig before subtracting.
- Ignoring gauge height. On a tall pump, a few feet between gauges is a few percent of the head.
- Using a pump curve in psi for another liquid. Convert the curve back to feet first.
To calculate the friction head a pump must overcome, you need the pipe friction factor; our Colebrook equation guide includes a solver, roughness values and Darcy–Weisbach examples.
Liquid head and pump pressure both load the pipe or tank wall; our hoop stress guide explains Pr/t, Barlow’s formula and thick-wall stresses with a calculator.
To estimate how much head a water pipe loses to friction, use the Hazen-Williams equation.
Frequently Asked Questions
How do you convert psi to feet of head?
Multiply psi by 2.31 and divide by the liquid’s specific gravity: head (ft) = psi × 2.31 ÷ SG. For water, SG is 1, so 50 psi = 115.5 ft of head.
How do you convert feet of head to psi?
Multiply feet of head by 0.433 and by the specific gravity: psi = ft × 0.433 × SG. For water, 120 ft of head = 52 psi.
How many feet of head is 1 psi?
2.31 ft of water. Using NIST’s factors the precise value is 2.3067 ft for water at its densest (39.2 °F), and about 2.31 ft at 60 °F.
How much pressure is 1 foot of water?
About 0.433 psi. Wilo’s pump handbook rounds it to 0.434 psi; either is fine for field work.
Why do pump curves use feet of head instead of psi?
A centrifugal pump adds the same head (energy per pound of liquid) whatever the liquid, so one curve in feet covers water, oil or glycol. The pressure that head produces depends on specific gravity, so a curve in psi would only be right for one liquid.
Does feet of head change with temperature?
The pressure for a given head does, slightly, because hot water is less dense. Engineering ToolBox gives water at 212 °F a density of 958 kg/m³, so 1 psi equals about 2.41 ft of head instead of 2.31.
How do you convert psi to meters of head?
Multiply psi by 0.703 and divide by SG. 100 psi of water is about 70.3 m of head. For bar, multiply by 10.2: 1 bar ≈ 10.2 m of water.
What is the difference between static head and dynamic head?
Static head is the height difference the liquid must be lifted. Dynamic head adds the friction loss in pipes and fittings and the velocity head. Total dynamic head (TDH) is what you read off the pump curve.
Is head in feet gauge or absolute pressure?
A pressure converted from a gauge reading is gauge head, the height of liquid the pressure could support above atmosphere. To work in absolute terms (for NPSH, for example) add atmospheric pressure first; see our psig vs psia guide.
How much pressure does a 100 ft water tower give?
About 43.3 psi at the base (100 × 0.433), before friction losses in the mains. Every 2.31 ft of height adds 1 psi.
Sources and Further Reading
- Engineering ToolBox: Pump head and pressure conversion: h = 2.31 p ÷ SG and p = 0.433 h SG with examples.
- Wilo: Pump engineering conversions and formulas (PDF): head table, velocity head and water horsepower.
- NIST SP 811, Appendix B.8: psi and foot of water in pascals.
- Engineering ToolBox: Specific gravity of liquids: SG definition and values.
- Engineering ToolBox: Water density and specific weight: density of water by temperature.
- Wikipedia: Hydraulic head: pressure, velocity and elevation head.