PSI to Feet of Head: Conversion Formula, Chart and Calculator

By editor 10 min read
Water tank with depth scale showing 2.31 feet of head equals 1 psi beside a pressure gauge

To convert psi to feet of head, multiply by 2.31 and divide by the liquid’s specific gravity (SG). To convert feet of head to psi, multiply by 0.433 and by SG. For water (SG 1.0), 1 psi = 2.31 ft of head and 1 ft of head = 0.433 psi, so 100 psi = 231 ft and 120 ft = 52 psi. Lighter liquids such as gasoline need more feet of head to make the same pressure; heavier ones such as glycol need less.

Head (ft) = psi × 2.31 ÷ SG   |   psi = ft × 0.433 × SG
2.31 ft
of water head per psi
0.433 psi
per foot of water
0.703 m
of water head per psi
10.2 m
of water head per bar

PSI to Feet of Head Formula

Engineering ToolBox gives the two pump-curve conversions as h = 2.31 p ÷ SG and p = 0.433 h SG, where h is head in feet, p is pressure in psi and SG is the specific gravity of the fluid. Wilo’s pump engineering handbook lists the same pair: 1 psi = 2.31 ft of water and 1 ft of water = 0.433 psi.

Where 2.31 comes from: NIST SP 811 lists 1 psi as 6,894.757 Pa and one conventional foot of water as 2,989.067 Pa, so 1 psi supports 6,894.757 ÷ 2,989.067 = 2.3067 ft of water at its densest. At 60 °F water is 0.1% lighter, which rounds to the familiar 2.31.

Water column depth compared with the pressure at its baseAn open tank of water marked every 2.31 feet of depth. Each 2.31 feet adds 1 psi, so 23.1 feet of water gives 10 psi on a gauge at the bottom. One foot of water head is 0.433 psi.A 2.31 ft column of water presses down with 1 psiopen tank0.00 ft0 psi4.62 ft2 psi9.24 ft4 psi13.86 ft6 psi18.48 ft8 psi23.10 ft10 psidepthpressurewater surface10Water (SG 1.0)1 psi = 2.31 ft of head1 ft of head = 0.433 psi23.1 ft deep → 10 psi100 ft tower → 43.3 psi100 psi → 231 ft of headIndustrialBasicsindustrialbasics.com
Figure 1: For water, every 2.31 ft of depth adds 1 psi (gauge). Values from Engineering ToolBox and Wilo.

Worked examples

  • 40 psi to feet of head (water): 40 × 2.31 = 92.4 ft.
  • 150 ft of head to psi (water): 150 × 0.433 = 65.0 psi.
  • 60 psi of diesel-type fuel oil (SG 0.893): 60 × 2.31 ÷ 0.893 = 155 ft.
  • 80 ft of sea water (SG 1.028) to psi: 80 × 0.433 × 1.028 = 35.6 psi.

PSI to Feet of Head Calculator

PSI to Feet of Head Calculator
IndustrialBasics calculator. Uses NIST factors (1 psi = 6,894.757 Pa; 1 ft of water = 2,989.067 Pa), so head (ft) = psi × 2.3067 ÷ SG, with SG relative to water at 4 °C. Specific gravities from Engineering ToolBox.

PSI to Feet of Head Chart (Water)

psift of headpsift of head
1 psi2.3 ft60 psi138.5 ft
2 psi4.6 ft70 psi161.6 ft
5 psi11.5 ft80 psi184.7 ft
10 psi23.1 ft90 psi207.8 ft
15 psi34.6 ft100 psi230.9 ft
20 psi46.2 ft125 psi288.6 ft
25 psi57.7 ft150 psi346.3 ft
30 psi69.3 ft200 psi461.7 ft
40 psi92.3 ft250 psi577.2 ft
43.3 psi100.0 ft300 psi692.6 ft
50 psi115.4 ft500 psi1154.4 ft
Water at 60 °F (SG 0.999). Head = psi × 2.309. Calculated from NIST factors and the Engineering ToolBox water density table.

Feet of Head to PSI Chart (Water)

ft of headpsift of headpsi
1 ft0.43 psi75 ft32.49 psi
2 ft0.87 psi80 ft34.65 psi
5 ft2.17 psi100 ft43.31 psi
10 ft4.33 psi120 ft51.98 psi
20 ft8.66 psi150 ft64.97 psi
23.1 ft10.01 psi200 ft86.63 psi
25 ft10.83 psi231 ft100.05 psi
30 ft12.99 psi250 ft108.28 psi
40 ft17.33 psi300 ft129.94 psi
50 ft21.66 psi400 ft173.25 psi
60 ft25.99 psi500 ft216.57 psi
Water at 60 °F. psi = ft × 0.433. A gauge reads these values in psig at the bottom of an open column.

Why Specific Gravity Matters

Specific gravity is the ratio of a liquid’s density to the density of water at 4 °C (39.2 °F), the definition Engineering ToolBox uses. A column of a lighter liquid weighs less, so it must be taller to press down with the same psi.

Feet of head produced by 100 psi in five liquids100 psi equals about 312 feet of gasoline, 281 feet of kerosene, 231 feet of water, 224 feet of sea water and 210 feet of ethylene glycol.The same 100 psi lifts lighter liquids higherGasoline (SG 0.739)312 ftKerosene (SG 0.82)281 ftWater (SG 1.0)231 ftSea water (SG 1.028)224 ftEthylene glycol (SG 1.10)210 ftHead = psi × 2.31 ÷ SG. A pump curve in feet is the same for every liquid; the gauge psi changes with SG.IndustrialBasicsindustrialbasics.com
Figure 2: Specific gravities from Engineering ToolBox. Lighter liquids need more feet of head for the same pressure.
LiquidSpecific gravityft of head per psipsi per ft of head
Water, 60 °F (15 °C)0.99912.310.433
Water, 140 °F (60 °C)0.98322.350.426
Water, 212 °F (100 °C)0.958352.410.415
Sea water1.0282.240.446
Ethylene glycol1.12.100.477
Fuel oil0.8932.580.387
Kerosene0.822.810.355
Gasoline (vehicle)0.7393.120.320
Specific gravities from Engineering ToolBox (water values from its density table: 999.1, 983.2 and 958.35 kg/m³). Check your product’s data sheet for the exact SG.

This is why Engineering ToolBox notes that pump curves are drawn in feet or meters of head. A pump that develops 231 ft of head makes 100 psi on cold water but only about 74 psi on gasoline (231 × 0.433 × 0.739), even though the impeller is doing the same job.

Sizing tip: When you buy a pump to move anything other than cold water, convert the required pressure to head with the real SG before you read the curve. Using 2.31 for a light hydrocarbon undersizes the pump; using it for brine or glycol oversizes it.

Converting Pump Gauge Readings to Total Head

Field technicians often check a pump against its curve with a suction and a discharge gauge. The pressure the pump adds, converted to feet, plus the height between the two gauges, gives the total head it is developing:

Total head (ft) = (Pdischarge − Psuction) × 2.31 ÷ SG + Δz
Total pump head from suction and discharge gauge readingsA pump with 5 psig on the suction gauge and 65 psig on the discharge gauge, with the discharge gauge 2 feet higher, develops about 141 feet of total head when pumping cold water.Reading pump head from two gaugescentrifugal pump5suction5 psig65discharge65 psigΔz = 2 ftTotal head (water, 60 °F)(65 − 5) × 2.31 + 2= 141 ftsame pipe size both sidesIndustrialBasicsindustrialbasics.com
Figure 3: Differential pressure × 2.31 ÷ SG, plus the height between gauges. Add the velocity-head difference if pipe sizes differ.
  1. Read both gauges in the same units. A suction gauge below atmospheric reads in inHg vacuum; convert it to a negative psig first (1 inHg = 0.491 psi).
  2. Subtract suction from discharge to get the pressure the pump adds.
  3. Convert to feet with × 2.31 ÷ SG.
  4. Add the height difference between the gauge centers (Δz), positive if the discharge gauge is higher.
  5. Add the velocity-head difference if the suction and discharge pipes differ in size. Wilo gives velocity head as v² ÷ 64.4, with v in ft/s.

With 5 psig suction, 65 psig discharge and 2 ft between gauges on cold water, the pump develops (65 − 5) × 2.31 + 2 = 141 ft. Find that head on the curve to read the flow the pump should be delivering. If it does not match, the impeller may be worn, the pump may be running backward, or the gauges may be wrong.

From feet of head to pump power

Head also sets how much power the liquid receives. Wilo’s formula sheet gives water horsepower = gpm × head (ft) × SG ÷ 3,960; dividing by pump efficiency gives the shaft power the motor must supply. 200 gpm at 135 ft of water is 200 × 135 ÷ 3,960 = 6.8 water hp. To express that in kilowatts, see our kW to hp conversion.

Safety note: Pressure gauges on pump discharge lines can see surges well above normal readings. Isolate and bleed a gauge before removing it, and never stand in line with a gauge on a pressurized system that may fail.

Static Head, Pressure Head and Velocity Head

TermWhat it meansTypical use
Static head (elevation head)Height of the liquid surface above the point of interestTank level, water tower pressure, lift from sump to roof
Pressure headPressure expressed as a height of liquid: p ÷ (ρg)Converting gauge psi to feet on a pump curve
Velocity headKinetic energy as a height: v² ÷ 2g (v² ÷ 64.4 in ft/s)Correcting gauge readings where pipe sizes change
Friction headEnergy lost to friction in pipe, valves and fittingsSystem curve and pump selection
Total dynamic head (TDH)Static + friction + velocity head the pump must supplyReading flow off a pump curve
Head terms. The Wikipedia hydraulic head article defines total head as pressure head + velocity head + elevation head (Bernoulli’s equation).

Wikipedia’s hydraulic head article also notes that pressure head depends on the density of the liquid, which changes with temperature and salinity, so measurements are standardized to fresh water when they need to be compared. That is the same reason the calculator above lets you pick hot water or sea water.

Using Head to Measure Tank Level

The relationship works in reverse for level measurement. A pressure transmitter at the bottom of an open tank reads the head of liquid above it, so level (ft) = psi × 2.31 ÷ SG. A gauge transmitter reading 8.66 psi under water means about 20 ft of level; if the tank holds glycol at SG 1.10, the same reading means only about 18.2 ft.

Use a gauge (vented) transmitter on open tanks so atmospheric changes cancel out, and set the SG in the transmitter or PLC scaling. Our psig vs psia guide explains vented versus absolute sensors, and types of industrial sensors covers other level technologies.

Common Mistakes

  • Leaving out specific gravity. 2.31 is only right for water.
  • Dividing when you should multiply. Head in feet is always the bigger number for water: 1 psi is 2.31 ft, not 0.433 ft.
  • Mixing gauge and absolute values. Convert both gauges on the same basis, and convert vacuum readings to negative psig before subtracting.
  • Ignoring gauge height. On a tall pump, a few feet between gauges is a few percent of the head.
  • Using a pump curve in psi for another liquid. Convert the curve back to feet first.

To calculate the friction head a pump must overcome, you need the pipe friction factor; our Colebrook equation guide includes a solver, roughness values and Darcy–Weisbach examples.

Liquid head and pump pressure both load the pipe or tank wall; our hoop stress guide explains Pr/t, Barlow’s formula and thick-wall stresses with a calculator.

To estimate how much head a water pipe loses to friction, use the Hazen-Williams equation.

Frequently Asked Questions

How do you convert psi to feet of head?

Multiply psi by 2.31 and divide by the liquid’s specific gravity: head (ft) = psi × 2.31 ÷ SG. For water, SG is 1, so 50 psi = 115.5 ft of head.

How do you convert feet of head to psi?

Multiply feet of head by 0.433 and by the specific gravity: psi = ft × 0.433 × SG. For water, 120 ft of head = 52 psi.

How many feet of head is 1 psi?

2.31 ft of water. Using NIST’s factors the precise value is 2.3067 ft for water at its densest (39.2 °F), and about 2.31 ft at 60 °F.

How much pressure is 1 foot of water?

About 0.433 psi. Wilo’s pump handbook rounds it to 0.434 psi; either is fine for field work.

Why do pump curves use feet of head instead of psi?

A centrifugal pump adds the same head (energy per pound of liquid) whatever the liquid, so one curve in feet covers water, oil or glycol. The pressure that head produces depends on specific gravity, so a curve in psi would only be right for one liquid.

Does feet of head change with temperature?

The pressure for a given head does, slightly, because hot water is less dense. Engineering ToolBox gives water at 212 °F a density of 958 kg/m³, so 1 psi equals about 2.41 ft of head instead of 2.31.

How do you convert psi to meters of head?

Multiply psi by 0.703 and divide by SG. 100 psi of water is about 70.3 m of head. For bar, multiply by 10.2: 1 bar ≈ 10.2 m of water.

What is the difference between static head and dynamic head?

Static head is the height difference the liquid must be lifted. Dynamic head adds the friction loss in pipes and fittings and the velocity head. Total dynamic head (TDH) is what you read off the pump curve.

Is head in feet gauge or absolute pressure?

A pressure converted from a gauge reading is gauge head, the height of liquid the pressure could support above atmosphere. To work in absolute terms (for NPSH, for example) add atmospheric pressure first; see our psig vs psia guide.

How much pressure does a 100 ft water tower give?

About 43.3 psi at the base (100 × 0.433), before friction losses in the mains. Every 2.31 ft of height adds 1 psi.

Sources and Further Reading

About the author

editor