Electrical Safety PPE: A Complete Guide to Requirements, Types and Checklist

By editor Updated 27 min read
Electrical safety PPE: insulated glove, safety helmet and shield with lightning bolt, with IndustrialBasics branding

Short answer. Electrical safety PPE is the protective equipment that limits injury from the two main electrical hazards: electric shock and arc flash. They need different kit. Rubber insulating gloves (worn under leather protectors), insulating sleeves and mats guard against shock. Arc-rated clothing, a face shield or hood, safety glasses and hearing protection guard against arc flash burns and blast. A Class E safety helmet and electrical hazard footwear add head and foot protection. What you need depends on a task-specific risk assessment, the voltage and the incident energy. PPE is the last line of defence: make the equipment dead, isolate it and prove it dead first.

6 monthsUS retest interval for rubber insulating gloves in service
1.2 cal/cm²commonly cited second-degree burn threshold on bare skin
20,000 Vtest voltage for a Class E safety helmet
2,070US workplace electrical deaths, 2011–2024

Electrical work can hurt you in several ways at once: current through the body (shock), a burst of heat and light (arc flash), a pressure wave (arc blast), burns, and flying metal and debris. No single item of PPE covers all of them. This guide explains which equipment protects against which hazard, how to choose and check it, and which rules and standards apply in the US, UK and India.

What electrical safety PPE protects against

Electric shock

Electric shock happens when current passes through your body, usually after you touch a live part or a conductor that has become live. It can cause burns, muscle lock, heart problems and falls. Typical causes are exposed live parts, damaged insulation, wet conditions and faulty tools. The path current takes also depends on the installation’s earthing system.

Insulating PPE (rubber gloves, sleeves, mats) puts a rated barrier between you and the live part. Low voltage is not safe by default: HSE warns that a shock can cause serious or fatal injury even when an RCD is fitted.

Arc flash

An arc flash is a sudden release of heat and light when current jumps through air between conductors, or from a conductor to earth. A dropped tool, dust, moisture, worn insulation or a switching error can start one. You do not need to touch anything to be hurt. The arc core is commonly quoted at up to about 35,000°F (around 19,400°C), and as little as 1.2 calories per square centimetre (cal/cm²) can cause a second-degree burn on bare skin.

The risk is highest around switchgear and busbars. Arc-rated clothing and face protection reduce the heat reaching your skin. For causes, boundaries and incident energy, see our full guide to arc flash.

Arc blast

An arc blast is the pressure wave from the same event. Heated air and vaporised metal expand violently, throwing molten droplets and debris with a very loud bang. Injuries include blast trauma, shrapnel wounds, hearing damage and falls. A face shield or hood, safety glasses and hearing protection reduce exposure.

Electrical burns and secondary injuries

Current can burn tissue along its path, so internal damage can be worse than the skin suggests. Arcs also ignite clothing, and melting synthetic fabric deepens burns. Eyes face flash and flying particles, and ears face blast noise. Protection must therefore cover the head, face, eyes, ears, body, arms, hands and feet, not just the hands.

Why electrical safety PPE matters

Used correctly, PPE reduces how badly you are hurt when a control fails. It also helps an employer show that it assessed the risk and provided suitable protection. The US figures below show how serious the problem still is.

Pie chart of US electrical fatalities by occupation type72 per cent of OSHA-reported electrical fatalities from 2011 to 2024 were in non-electrical occupations and 28 per cent in electrical occupations.Who is killed by electricity at work?OSHA-reported US workplace electrical fatalities, 2011–2024 (1,607 cases)72%28%Non-electrical occupations1,163 deathsElectrical occupations444 deathsMost victims were not electricians.They were roofers, labourers, drivers andpainters who met overhead lines or live kit.Source: ESFI analysis of OSHA data, March 2026. Percentages calculated from ESFI counts.
Roughly seven in ten victims worked outside electrical trades. ESFI quotes 70/30. The chart shows exact shares from its counts.
Bar chart of causes of US electrical fatalitiesOverhead power line contact caused 49 per cent of deaths, unexpected contact with energy 20 per cent, nearby energised equipment 12 per cent, and arc flash 2 per cent.What kills in electrical incidents?Share of US electrical fatalities by cause, 2011–2024Overhead power line contact49%Unexpected contact with energy20%Nearby energised equipment12%Working on energised parts4%Ground faults4%Damaged wiring or equipment3%Arc flash2%Other / unspecified6%Source: ESFI, workplace electrical statistics 2011–2024. “Other” is the remainder after the listed causes.Arc flash is 2% of deaths (26 cases). These figures count deaths only, not non-fatal burn injuries.
Overhead power line contact is the biggest killer. Arc flash is a small share of deaths but a major source of burns.

Two lessons follow. First, many victims were not electricians, so electrical hazard training matters well beyond the electrical trade. Second, PPE does little against an overhead line strike. Planning, clearance distances and isolation do. That is why PPE sits last in the hierarchy of controls.

Safety first: the hierarchy of controls and de-energisation

What is the hierarchy of controls?

The hierarchy ranks safety measures from most to least effective. Always start at the top.

Hierarchy of controls diagram for electrical safetyFive levels from most to least effective: elimination, substitution, engineering controls, administrative controls and personal protective equipment.Hierarchy of controls for electrical workMost effective at the top, least effective at the bottom1. EliminationWork dead. Remove the hazard or the task.2. SubstitutionUse lower-voltage or safer equipment.3. Engineering controlsInsulation, barriers, arc-flash relays, remote racking.4. Administrative controlsProcedures, permits, labels, training, isolation and lock-off.5. PPELast line of defence.Based on the hierarchy of controls used by HSE and OSHA. PPE reduces the harm from a hazard that is still there.
PPE is the final barrier, used when higher controls cannot remove the risk.

Why PPE is the last line of defence

PPE does not remove the hazard. It only reduces harm if something goes wrong, and only if it is the right type, fits, is undamaged and is worn. HSE describes PPE as a last line of defence where risk cannot otherwise be eliminated or controlled. Higher controls protect everyone nearby, not just the wearer. Examples include faster-acting protection such as the right fuse or circuit breaker, well-set protection coordination that clears faults quickly, and regular relay testing so protection trips when it should.

De-energisation, lockout/tagout and isolation

The safest electrical work is done dead. In the UK this means isolation, lock-off and proving dead. In the US it is called lockout/tagout (LOTO). The steps are the same in principle:

  1. Switch off and isolate every source of supply.
  2. Lock off and tag the isolation point so nobody can re-energise it.
  3. Test with a suitable instrument that you have proved works, then prove it again.
  4. Only then start work, still alert to stored energy and other hazards.

HSE says supplies should be made dead and proved dead before work starts, with isolation that prevents re-energisation. Our lockout/tagout procedure guide covers the process in detail.

When can live work be considered?

Rarely. HSE says live work is acceptable only after it has been decided that working dead is unreasonable. Under the Electricity at Work Regulations 1989, HSG85 sets three conditions that must all be met. If any one fails, work dead. In the US, NFPA 70E expects energised work to be justified and, where required, permitted.

PPE does not make live work safe. HSE states plainly that it is never absolutely safe to work on live electrical equipment. Live work needs specific justification, a written procedure and qualified people. PPE reduces the harm if something goes wrong. It is not permission to work live.

Shock protection vs arc flash protection

Many articles blur this point, and mixing the two causes real injuries. Shock PPE and arc flash PPE do different jobs and cannot replace each other.

Shock protection PPE

It stops current passing through your body. It includes rubber insulating gloves, insulating sleeves, mats and blankets, and dielectric overshoes. Selection depends on voltage and the shock risk.

Arc flash protection PPE

It limits the thermal energy reaching your skin. It includes arc-rated clothing, face shields, balaclavas, hoods and arc flash suits. Selection depends on the assessed arc flash exposure.

ComparisonShock protectionArc flash protection
Main hazardCurrent through the bodyThermal burns, plus blast, light and noise
Main purposeStop current passing through youReduce the heat reaching your skin
Main equipmentRubber gloves, sleeves, mats, dielectric overshoesArc-rated clothing, face shield or hood, balaclava, suit
Selection basisVoltage and shock riskIncident energy and hazard assessment
Key standardsASTM D120, ASTM F496, IEC 60903ASTM F1506, ASTM F1959, ASTM F2178, NFPA 70E
Important limitGives no arc flash heat protectionGives no shock insulation

Can one type of PPE protect against both?

No. Rubber insulating gloves are tested for insulation, not for arc heat. Arc-rated clothing resists heat, not current. On the same live task you may need both, chosen so they work together. Never assume that one set of PPE covers the other hazard.

Electrical safety PPE checklist

Use this as a quick reference. The final list depends on your task risk assessment.

PPE itemMain protectionHazard
Rubber insulating glovesElectric shockShock
Leather protector glovesProtect rubber gloves from cuts and puncturesShock (support)
Insulating sleevesArm and shoulder contact with live partsShock
Insulating mats and blanketsContact with live parts or earthShock
Insulated toolsReduce accidental contactShock
Arc-rated clothingArc flash heatArc flash
Arc flash suitHigher arc flash exposureArc flash
Arc-rated face shieldFace protectionArc flash
Arc-rated balaclava or hoodHead and neckArc flash
Electrical safety helmet (Class E)Head impact and electrical contactBoth
Safety glassesFlying particles and debrisBoth
Hearing protectionBlast noiseArc flash
Electrical hazard footwearSecondary protection against live-circuit contactShock

Insulating mats, blankets and tools are work equipment rather than wearable PPE in some frameworks, but they appear on the same task plan, so they are listed here.

Shock protection PPE: gloves, sleeves and footwear

Rubber insulating gloves

Rubber insulating gloves are the main shock protection when hands may touch live parts. Choose the class from the highest voltage that could be present and check the class marking. OSHA 1910.137 requires inspection before each day’s use, with an air test for gloves. Limits: they give no arc flash heat protection, and ozone, oil, heat, cuts and punctures degrade them.

Glove classes and voltage ratings

Gloves are sorted into six classes by maximum use voltage. Values below are AC rms from OSHA Table I-4, checked on 9 November 2026. DC maximums are higher. Re-verify against the current OSHA table or ASTM D120 before you rely on them.

ClassMaximum use voltage (AC rms)What to check
00500 VMarked class, test date, system voltage
01,000 VMarked class, test date, system voltage
17,500 VMarked class, test date, system voltage
217,000 VMarked class, test date, system voltage
326,500 VMarked class, test date, system voltage
436,000 VMarked class, test date, system voltage
Bar chart of insulating glove classes and maximum use voltagesClass 00 500 volts, Class 0 1,000 volts, Class 1 7,500 volts, Class 2 17,000 volts, Class 3 26,500 volts, Class 4 36,000 volts AC rms.Rubber insulating glove classesMaximum use voltage (AC rms), OSHA 29 CFR 1910.137 Table I-4Class 00500 VClass 01,000 VClass 17,500 VClass 217,000 VClass 326,500 VClass 436,000 VCheck the class marked on the glove against the highest voltage that can be present. Re-verify against the current OSHA tableor ASTM D120 before you rely on this chart. Checked 9 November 2026.
Each step up the classes allows a much higher working voltage.

Which class for 480 V? On voltage alone, both Class 00 (500 V) and Class 0 (1,000 V) cover a 480 V system. Many sites choose Class 0 for margin, which is good practice rather than a rule. Always compare the maximum use voltage with the highest voltage that could appear, then follow your risk assessment.

Leather protector gloves

Leather protectors go over the rubber gloves to guard against cuts, punctures and abrasion. OSHA requires them, with limited exceptions, and says gloves used without protectors must be tested before reuse. Ordinary leather work gloves are not a substitute. Use protectors made for the job (ASTM F696 in the US) that fit snugly without bunching.

Insulating sleeves

Sleeves protect the arms and shoulders when you reach into equipment where bare arms could touch live parts. OSHA’s retest interval for sleeves is 12 months, plus the usual triggers. Inspect them before each day’s use.

Dielectric boots and electrical hazard footwear

Electrical hazard (EH) footwear, rated to ASTM F2413 in the US, has non-conducting soles and heels. It is secondary protection against accidental contact with live circuits, mainly in dry conditions. Wet, worn or contaminated soles lose that value.

Dielectric overshoes (ASTM F1117) are designed to insulate, so they can form part of primary shock protection where your risk assessment calls for it. Never treat EH boots as a substitute for gloves or isolation.

Insulating mats and blankets

Mats and blankets cover live parts or the floor so a slip or stray contact does less harm. HSG85 names insulating matting under BS EN 61111:2009, and OSHA tests blankets before first issue and every 12 months. Inspect before use and replace damaged ones.

Insulated tools

Insulated screwdrivers, pliers and cutters reduce accidental contact when work cannot be made dead. HSG85 names BS EN 60900:2012 for hand tools up to 1,000 V AC and 1,500 V DC. Look for the rating mark on the tool, and take any tool with chipped, cracked or worn insulation out of service.

Arc flash PPE: clothing, suits and ratings

What is arc-rated clothing?

Arc-rated (AR) clothing is flame-resistant fabric that has also been tested for electric arc exposure and marked with an arc rating. It resists ignition and slows heat transfer so burns are less severe. You need it where the hazard assessment shows an arc flash risk. Typical garments are shirts, trousers, coveralls, jackets and hoods.

Arc-rated shirts and trousers

Wear long sleeves and full-length trousers, fastened as the maker instructs, so no skin or non-rated fabric is exposed. Check the label for the arc rating, and inspect for holes, tears, damaged seams and contamination. Wash and repair only as the manufacturer allows. Do not add up the ratings of layers yourself: use the maker’s data and the standard.

Arc flash suits

An arc flash suit is a full set, usually a jacket, trousers or bib overalls and a hood with a face window. It is used for higher incident energy tasks. Choose it from the assessed incident energy, not the highest rating on the shelf. Suits are hot and heavy and reduce vision and dexterity, so an oversized rating adds its own risks.

Arc rating: ATPV and EBT explained

Four terms matter:

  • Incident energy: the heat energy that would reach a surface at a given distance during an arc, in cal/cm².
  • ATPV (Arc Thermal Performance Value): the energy level at which there is a 50% chance of a second-degree burn through the fabric.
  • EBT (Energy Breakopen Threshold): the energy level at which the fabric breaks open.
  • Arc rating: the ATPV or EBT, whichever is lower, marked on the garment in cal/cm². It is measured by the test method in ASTM F1959.

The rule is simple: the arc rating must meet or exceed the incident energy from your assessment. For example, if a label shows 8.5 cal/cm² at the stated working distance, garments rated below 8.5 are not suitable. This example is illustrative only and is not a selection instruction.

Flame-resistant (FR) vs arc-rated (AR) clothing

FeatureFR clothingArc-rated clothing
Main purposeResist ignition and flame spreadTested protection against electric arc exposure
Arc ratingNot necessarily markedMarked in cal/cm²
TestingDepends on its own standardArc tested (ASTM F1506 / F1959)
Use for electrical workNot automatically suitableSelected against the assessed hazard

All arc-rated clothing is flame-resistant, but not all flame-resistant clothing is arc-rated. ASTM F1506 covers both flame-resistant and arc-rated textiles, so check the label for an actual arc rating.

Why undergarments matter

Non-rated synthetic fabrics such as nylon and polyester can melt onto the skin in an arc event and deepen the burn. Wear non-melting underwear and socks, or AR undergarments, as the garment maker and the standard direct.

Head, eye, face and hearing protection

Electrical safety helmets (hard hats)

In the US, ANSI/ISEA Z89.1 gives helmets an electrical class. Impact protection and electrical protection are separate things, so check both marks.

ClassElectrical ratingUse for electrical work?
Class E (Electrical)Tested at 20,000 VYes, the class for electrical work
Class G (General)Tested at 2,200 VLimited low-voltage protection only
Class C (Conductive)NoneNo. Often vented and conductive

Inspect the shell and suspension before each use, and replace to the manufacturer’s date and service-life guidance. In the UK, ask the supplier for the standard marking that shows the helmet is suitable for electrical work.

Safety glasses and goggles

Safety glasses stop flying particles and debris. Choose impact-rated eyewear marked ANSI/ISEA Z87.1 (US) or BS EN 166 (UK), ideally with non-metal frames. Ordinary prescription glasses are not safety eyewear. Under an arc-rated shield, glasses still protect against debris that gets past the shield.

Arc flash face shields

An arc-rated face shield protects the face from heat, molten metal and debris, and its arc rating must match the assessed exposure (ASTM F2178 covers arc-rated face protection in the US). A shield alone leaves the head and neck exposed, so pair it with a balaclava or use a full hood.

Balaclavas and hoods

An arc-rated balaclava covers the head and neck under a face shield and helmet. A full arc flash hood covers the head, neck and face in one piece, usually as part of a suit. Whichever you choose, check that the shield, balaclava, helmet and glasses fit together without gaps.

Hearing protection

An arc blast produces a very loud bang. NFPA lists ear protection among typical electrical PPE. Earplugs that fit under a hood are common, and earmuffs may not fit under a face shield. The exact requirement depends on your assessment and local noise rules, so confirm it for your task.

OSHA, NFPA 70E and other standards

Not every rule is law. We label each item so you can tell the difference:

Legal requirement government regulation. Consensus standard voluntary technical standard. Manufacturer guidance maker’s instructions. General good practice accepted good practice.

OSHA electrical PPE requirements

OSHA is the US workplace safety regulator. The key rules are:

  • 29 CFR 1910.132 Legal requirement: general PPE hazard assessment, selection and training.
  • 29 CFR 1910.137 Legal requirement: design, in-service care and testing of insulating equipment.
  • 29 CFR 1910.335 Legal requirement: electrical protective equipment for the body part and task.
  • 29 CFR 1926.97 Legal requirement: the construction equivalent of 1910.137.
  • 29 CFR 1910.269 Legal requirement: electric power generation, transmission and distribution, including clothing that will not melt or ignite.

OSHA does not require “NFPA 70E PPE” as a blanket rule. Its enforceable duties come through these provisions and your hazard assessment. See OSHA’s page on electric arc flash hazards and the construction rule 1926.97.

What is NFPA 70E?

NFPA 70E is the Standard for Electrical Safety in the Workplace. It Consensus standard sets out safe work practices, risk assessment and PPE selection for shock, arc flash and arc blast. OSHA describes it as guidance that helps employers comply with its electrical rules, but has not adopted it wholesale. Many employers follow it to show compliance.

The 2024 edition took effect on 13 May 2023. NFPA has since announced a 2027 edition with changes that include an extra person for certain justified energised work, tighter evidence that arc-rated PPE meets its standard, and new wording on testing for absence of voltage. Confirm the edition and effective date on NFPA’s site before you update your programme.

NFPA 70E lets you choose PPE by an incident energy analysis or by the arc flash PPE category method. Do not treat category numbers as universal. They only apply when the table’s conditions are met.

Important ASTM standards

Five ASTM standards matter most. All are Consensus standard voluntary standards, though regulators reference some of them. D120 is the specification for rubber insulating gloves. F496 covers in-service care and testing of insulating gloves and sleeves. F1506 covers flame-resistant and arc-rated clothing. F1959 is the test method that produces an arc rating. F2178 covers arc-rated face protection. The chart below adds the rest.

IEC and other international standards

IEC publishes international standards that Europe adopts as EN standards and the UK as BS EN. IEC 60903 (BS EN 60903) covers insulating gloves, and the IEC/EN 61482 series covers arc protective clothing. Check the current edition with the supplier.

Electrical PPE standards chart

PPE typeRelevant standardStatusMain purpose
Rubber insulating glovesASTM D120 / IEC 60903 (BS EN 60903)Consensus standardShock protection
Leather protectorsASTM F696Consensus standardProtect rubber gloves
In-service care of gloves and sleevesASTM F496Consensus standardCare and test methods
Insulating equipment testingOSHA 1910.137 / 1926.97Legal requirementTest intervals, inspection, certification
Arc-rated clothingASTM F1506 (F1506-25 is current)Consensus standardArc exposure protection
Arc rating testASTM F1959Consensus standardMeasures arc rating
Arc-rated face protectionASTM F2178Consensus standardFace protection
Safety helmetsANSI/ISEA Z89.1Consensus standardImpact and electrical classes
Electrical hazard footwearASTM F2413Consensus standardSecondary shock protection
Dielectric overshoesASTM F1117Consensus standardInsulating footwear

Standards are copyrighted and revised often. Use this chart to know what to ask for, then read the official text, such as ASTM F1506, for exact requirements.

Electrical safety PPE requirements in the US, UK and India

United States

OSHA enforces the rules above, and NFPA 70E and ASTM standards fill in the technical detail. Employers must assess hazards, provide suitable PPE, train workers and certify testing of insulating equipment. Workers must use PPE correctly and report damage.

United Kingdom

HSE enforces electrical safety in Great Britain. The main laws are:

  • Electricity at Work Regulations 1989 Legal requirement: prevent danger, and allow live work only when all three conditions are met. Regulation 4(4) requires protective equipment to be suitable, maintained and properly used.
  • Personal Protective Equipment at Work Regulations 1992, as amended Legal requirement: employers must provide suitable PPE free of charge, maintain it and train people to use it.
  • HSG85, Electricity at work: safe working practices General good practice: HSE guidance. It names insulating gloves and matting, and thermally insulating flame-resistant PPE where arc burns cannot be avoided, and says PPE should be inspected frequently and replaced if damaged.

BS EN standards such as BS EN 60903 (gloves), BS EN 61111 (matting) and BS EN 60900 (hand tools) define product performance. HSE sets no single fixed glove retest interval, so follow the standard, the manufacturer and your risk assessment. BS 7671 covers how installations are designed and installed. It is not a PPE standard.

India

The Central Electricity Authority (CEA) sets safety rules under the Electricity Act 2003. The CEA (Measures relating to Safety and Electric Supply) Regulations, 2023, were notified in June 2023 and cover tools and PPE such as rubber gloves and rubber safety footwear for electrical work. The Bureau of Indian Standards (BIS) publishes the product standards.

A CEA public-comment draft list of relevant standards names IS 4770 (rubber gloves), IS 2925 (industrial helmets) and IS 1989 (safety footwear). It is a draft, so confirm the final list and current BIS editions, and check for amendments to the regulations, before you make a compliance claim.

RegionEnforcerKey legal basisMain technical standards
United StatesOSHA29 CFR 1910 Subparts I and S; 1926 Subpart E and KNFPA 70E, ASTM, ANSI/ISEA
United KingdomHSEElectricity at Work Regulations 1989; PPE at Work Regulations 1992BS EN, IEC
IndiaCEA (with BIS for products)Electricity Act 2003; CEA Safety Regulations 2023BIS (IS) standards, IEC

How to choose the right electrical safety PPE

Selection is a risk assessment, not a shopping list. Work through these steps in order.

  1. Identify the hazards. Decide whether the task has a shock hazard, an arc flash hazard or both. Consider the equipment, the environment and what could go wrong.
  2. Check the voltage. Find the highest voltage that could be present and match insulating equipment to it. Verify the class marking on gloves and sleeves.
  3. Check the arc flash incident energy. Use the assessment or equipment label. Choose clothing, face and head protection with an arc rating that meets or exceeds it. Make sure the label’s date and method are current.
  4. Check standards and certification. Look for the standard on the label (ASTM, IEC, ANSI/ISEA, EN) and follow the manufacturer’s instructions. Reject damaged or unmarked items.
  5. Check fit and compatibility. Gloves, sleeves, clothing, helmet, shield and glasses must fit properly, allow movement and work together.
  6. Put a qualified person in charge. A qualified electrical worker, electrical safety engineer or competent safety officer should select PPE and sign off the task.
Flowchart for choosing electrical safety PPEStart by asking whether the equipment can be made dead. If live work is justified, assess shock and arc flash risks separately, choose matching PPE, then check fit and condition.How to choose electrical PPE1. Can the equipment be made dead?YesNoWork deadIsolate, lock off, prove deadLive work only if justifiedPermit, qualified person, planThen still check other hazards2. Assess shock and arc flash riskShock hazardInsulating gloves + protectors, sleeves, matsArc flash hazardArc-rated clothing, face shield or hood, hearingMatch glove class to voltageCheck marking and test dateMatch arc rating to the assessed exposureIncident energy or PPE category method3. Check fit, compatibility and conditionInspect before every use. Qualified person signs off the task.
Start by asking whether the equipment can be made dead. PPE selection only applies to the hazards that remain.

Electrical PPE inspection, testing and storage

Inspection finds damage before it hurts you. Testing proves the insulation still works. Storage keeps the equipment in good condition between uses.

Daily pre-use inspection

Check every item before use, and again after any incident that could have damaged it. Look for:

  • Cracks, holes, cuts, tears and punctures.
  • Ozone cracking, embedded objects, and swelling, softening, hardening or stickiness in rubber.
  • Contamination from oil, chemicals or paint.
  • Damaged stitching, seams or loose components.
  • Worn insulation on tools.
  • Cracked or clouded shields and damaged harnesses.
  • Missing or unreadable labels, class marks and test dates.

Remove defective equipment from service until it is repaired and retested, or replaced.

How often should rubber insulating gloves be tested?

Under OSHA 1910.137, gloves need an electrical test before first issue and every six months after. They also need a test whenever their insulating value is suspect, after repair, and after use without protectors. Gloves tested but not issued may go into service only if tested within the previous 12 months. Employers must certify that testing was done. Daily visual inspection and an air test still apply in between.

Timeline of insulating glove inspection and testingTest before first issue and every six months, inspect and air test every day of use, and retest after repair, suspected damage or use without protectors.Insulating glove inspection and testing timelineUS general industry rule, 29 CFR 1910.137IssueElectrical testbefore first issue6 monthsElectricalre-test12 monthsElectricalre-test18 monthsElectricalre-testEvery day of use: visual inspection and air test. Remove damaged gloves.Test again before reuse if: insulating value is suspect, after repair,or after use without leather protectors.Unissued gloves: only issue if tested within the previous 12 months.Source: OSHA 1910.137 Table I-5 and 1910.137(c), checked 9 November 2026.The UK has no single fixed interval. Follow BS EN 60903, the manufacturer and your risk assessment.
Daily checks happen between the scheduled electrical tests.

For example, gloves issued on 10 January 2026 would be due for their next electrical test by 10 July 2026 (illustrative dates). This is separate from an insulation resistance test on cables and equipment, which checks installed equipment, not your PPE.

Inspection and testing chart

PPE itemBefore each useElectrical testingSource of interval
Rubber insulating glovesVisual and air testBefore first issue, every 6 months, plus triggersOSHA 1910.137 Legal requirement
Insulating sleevesVisualBefore first issue, every 12 months, plus triggersOSHA 1910.137 Legal requirement
Insulating blanketsVisualBefore first issue, every 12 months, plus triggersOSHA 1910.137 Legal requirement
Leather protectorsVisual for cuts and contaminationNo fixed OSHA electrical testManufacturer Manufacturer guidance
Arc-rated clothingHoles, seams, contamination, labelsNone. Care as the maker directsManufacturer Manufacturer guidance
Face shield, hood, balaclavaCracks, clouding, fit, harnessNoneManufacturer Manufacturer guidance
Safety helmetShell and suspensionNoneManufacturer Manufacturer guidance
EH footwearSoles, uppers, markingsNoneManufacturer Manufacturer guidance

Storage requirements

OSHA requires insulating equipment to be cleaned as needed and stored away from light, temperature extremes, excessive humidity and ozone. As good practice, and per most manufacturers:

  • Keep gloves and sleeves clean, dry and uncrushed, not folded or creased.
  • Keep them away from sharp objects, oil and chemicals.
  • Store arc-rated clothing clean and dry, away from heat and contamination.
  • Follow the manufacturer’s storage instructions for each item.

When to replace PPE

Replace an item when it shows visible damage, fails inspection or testing, has an expired or unknown test status, is contaminated or deteriorating, or reaches the manufacturer’s replacement limit.

Electrical safety training and qualified person requirements

Who is a qualified electrical worker?

In the US, a qualified person has demonstrated skills and knowledge in the construction and operation of electrical equipment and installations and has received safety training to identify and avoid the hazards. In the UK the equivalent is a competent person. They understand the electrical hazards, know the protective equipment and can use it correctly.

Employer responsibilities

  • Assess workplace electrical hazards.
  • Provide suitable PPE.
  • Arrange training on hazards, PPE use, inspection, limitations and emergency response.
  • Keep inspection, test and certification records.
  • Make sure safe work procedures, including isolation, are followed.

Worker responsibilities

  • Wear the PPE the task requires.
  • Inspect it before use.
  • Follow instructions and the safe system of work.
  • Report damaged equipment.
  • Never misuse electrical protective equipment.

Downloadable electrical safety PPE checklist

Use this one-page checklist before each task. It is built for electricians, supervisors and safety officers.

CheckDone
Task description, location and risk assessment reference recorded☐
Equipment de-energised, isolated, locked off and proved dead (or live work justified and permitted)☐
Qualified or competent person confirmed☐
Hazard identified: shock, arc flash, or both☐
Required PPE listed for the task☐
PPE inspected before use (gloves air tested)☐
Glove class checked against voltage; test date in date☐
Arc rating checked against assessed incident energy☐
Standards and ratings verified on labels☐
Leather protectors fitted and undamaged☐
Head, eye, face, hearing and foot protection checked☐
Storage condition checked☐
Supervisor or safety officer sign-off, date and comments☐

Common electrical safety PPE mistakes to avoid

  • Using ordinary gloves instead of rated insulating gloves. Only rated rubber gloves insulate.
  • Wearing rubber gloves without protectors. Cuts and punctures can go unseen. Retest if used without them.
  • Confusing FR with arc-rated clothing. Look for a marked arc rating.
  • Choosing PPE without a hazard assessment. No assessment means no basis for the choice.
  • Using damaged insulating equipment. Remove it from service.
  • Ignoring glove test dates. Out-of-date gloves must not be used.
  • Using the wrong helmet. Class C helmets give no electrical protection.
  • Assuming safety footwear replaces insulating equipment. EH boots are secondary protection.
  • Wearing an arc rating that does not match the assessed exposure. Too low is dangerous. Far too high adds heat stress.
  • Treating PPE as a replacement for de-energisation. It never is.

Your meter is part of your protection too: see multimeter CAT ratings explained.

Frequently asked questions about electrical safety PPE

What PPE is required for electrical work?

It depends on the task, voltage and risk assessment. Typically: insulating gloves with protectors (shock), arc-rated clothing with face, eye and hearing protection (arc flash), a Class E helmet and EH footwear. Make the equipment dead first.

What are the different types of electrical safety PPE?

Shock protection (gloves, sleeves, mats, dielectric overshoes), arc flash protection (arc-rated clothing, face shields, hoods, suits) and general protection (helmet, safety glasses, hearing protection, footwear).

What is the difference between shock PPE and arc flash PPE?

Shock PPE insulates you from current. Arc flash PPE limits the heat reaching your skin. One cannot replace the other.

What are the four categories of arc flash PPE?

NFPA 70E’s category method groups tasks into Categories 1 to 4, with minimum arc ratings of 4, 8, 25 and 40 cal/cm² in editions that use this table. They apply only when the table’s conditions are met, so they are not universal. Check your edition or use an incident energy analysis.

What class of electrical gloves do I need for 480 V?

Class 00 (500 V) and Class 0 (1,000 V) both exceed 480 V on voltage alone. Check the maximum use voltage against the highest voltage that could be present, and follow your risk assessment.

How often should electrical gloves be tested?

Under OSHA 1910.137, before first issue and every six months, plus after repair, suspected damage or use without protectors. Inspect and air test them every day of use.

Is flame-resistant clothing the same as arc-rated clothing?

No. All arc-rated clothing is flame-resistant, but flame-resistant clothing needs a marked arc rating to count as arc-rated.

Does OSHA require electrical safety PPE?

Yes. Employers must assess hazards and provide suitable protective equipment, and insulating equipment must meet OSHA’s inspection and testing rules. NFPA 70E is a consensus standard, not an OSHA regulation.

Can you work on live electrical equipment with PPE?

PPE does not make live work safe. Live work must be justified, planned and done by qualified people. Work dead wherever you can.

What is an arc flash suit used for?

It gives full-body arc flash protection for higher incident energy tasks. It combines a jacket, trousers or bib overalls and a hood.

Do electricians need dielectric boots?

Not always. EH boots give secondary protection. Dielectric overshoes are used where footwear must provide primary insulation, as your risk assessment decides.

What is the difference between Class E and Class C hard hats?

Class E helmets are tested at 20,000 V. Class C helmets give no electrical protection.

What is ATPV in electrical PPE?

Arc Thermal Performance Value, in cal/cm². It is the energy level at which there is a 50% chance of a second-degree burn through the fabric.

Can rubber gloves protect against arc flash?

No. They are tested for insulation, not arc heat. Choose hand protection for arc exposure from your assessment and the standard.

Do workers need PPE when equipment is de-energised?

Only treat equipment as dead once it is isolated, locked off and proved dead. Other workplace hazards may still need PPE.

Choosing the right electrical safety PPE

Electrical safety PPE protects against two different hazards, and the equipment for each is different. Insulating gloves, sleeves and mats guard against shock. Arc-rated clothing, face and head protection and hearing protection guard against arc flash. Choose by risk assessment, follow the regulations and standards that apply where you work, and inspect and test equipment on schedule. Download the checklist above, and remember that PPE is always the last line of defence, after elimination, isolation and engineering controls.

Sources and last reviewed

Last reviewed: 9 November 2026. Reviewed by: [Name, qualification and role of the qualified electrical safety reviewer to be added before publishing]. Next review: May 2027, or sooner after a new NFPA 70E edition, an OSHA, HSE or CEA change, or an ASTM, IEC or BIS revision.

DateChange
9 November 2026First published. Standards and figures checked against the sources below.

Sources

This guide is general information, not professional advice. PPE selection must follow a task-specific risk assessment by a qualified person and the regulations and standards that apply where you work.

About the author

editor

Leave a Comment