How to Measure Inductance: Methods, Formulas and Practical Techniques

By editor 7 min read
Inductor coil connected to an LCR meter and an oscilloscope showing a resonance peak and an RL time constant curve

The most accurate way to measure inductance is with an LCR meter set to the frequency the coil works at. Without one, you can calculate it: from the resonant frequency with a known capacitor, L = 1 ÷ (4π²f²C); from the RL time constant, L = τ × R; or from AC voltage and current, L = √(Z² − R²) ÷ 2πf. Whichever you use, remember a real coil has resistance and stray capacitance, and iron-cored coils change value with current.

MethodEquipmentFormulaBest for
LCR meterLCR meter, test fixtureDirect readingMost components, best accuracy
ResonanceSignal generator, scope, known capacitorL = 1 ÷ (4π²f²C)Small air-core and ferrite coils
RL time constantSquare-wave generator, scope, resistorL = τ × RLarger inductances
AC voltage and currentAC supply, voltmeter, ammeterL = √(Z² − R²) ÷ 2πfIron-cored coils at line frequency
Formulas from the University of Iowa and University of Toronto lab manuals and the Keysight Impedance Measurement Handbook.
Methods for measuring inductanceAn LCR meter reads inductance directly. The resonance method uses a known capacitor and L equals 1 over 4 pi squared f squared C. The time constant method uses L equals tau times R. The AC method finds reactance from impedance and resistance.Four ways to measure inductanceLCR meterDirect readingSet frequency and levelBest accuracyResonanceKnown C + signal generatorL = 1 ÷ (4π²f²C)Good for small LTime constantSquare wave + scopeL = τ × RGood for large LAC V and IKnown frequency supplyX = √(Z² − R²)Iron-core coilsIndustrialBasicsindustrialbasics.com
Figure 1: Pick the method to suit the coil and the equipment you have.

Method 1: LCR Meter

An LCR meter applies a small AC test signal and calculates L from the measured impedance and phase. Keysight’s Impedance Measurement Handbook stresses that the reading depends on how you set it up:

  • Test frequency: choose the frequency the inductor works at. Stray capacitance makes every inductor resonate at its self-resonant frequency (SRF). Keysight notes that above the SRF the capacitive reactance dominates, so the SRF sets the maximum usable frequency.
  • Test signal level: cored inductors depend on test signal current because of core hysteresis. Keysight recommends setting the level for a defined test current, using automatic level control where available.
  • DC bias: the inductance of a cored inductor falls as DC current rises toward core saturation. Use a bias source if the coil carries DC in service.
  • Equivalent circuit: for a low-reactance inductor, Keysight says the series L–Rs model is a good approximation. Use the parallel model for high-impedance parts.
  • Fixture: nearby metal changes readings through eddy currents, especially on open-flux-path inductors.
Equivalent circuit of a real inductorA real inductor has winding resistance Rs in series with its inductance, and stray capacitance Cp across the coil. Above the self-resonant frequency it behaves like a capacitor. Cored inductors also change value with current.A real inductor is not just L (simplified model)LRs (winding)Cp (between turns)What it meansRs: use the series modelfor low-impedance coilsCp: above the self-resonantfrequency the coil actslike a capacitorCore: L changes with currentIndustrialBasicsindustrialbasics.com
Figure 2: Based on the inductor model in the Keysight Impedance Measurement Handbook.

Method 2: Resonance With a Known Capacitor

Connect the coil with a known capacitor and a series resistor to a signal generator. Sweep the frequency and watch the voltage across the resistor on an oscilloscope. The University of Iowa lab manual shows the series RLC circuit has a resonance where the current peaks, at:

f = 1 ÷ (2π√(LC))   so   L = 1 ÷ (4π²f²C)

Use a stable film capacitor of known value. The coil’s own stray capacitance adds to C, so pick a capacitor much larger than that stray value. This method is easy for small air-core and ferrite inductors.

Method 3: RL Time Constant

Drive the coil through a resistor with a low-frequency square wave and look at the resistor voltage, which follows the current. The current rises toward its final value with a time constant τ, the time to reach about 63% of the step. Then:

L = τ × Rtotal

The University of Toronto lab manual warns that a coil “is not a pure inductance, but acts as if there were a perfect inductance in series with a resistance”, its internal resistance. Include that resistance in Rtotal: measure it with an ohmmeter and add it to the series resistor and the generator’s output resistance.

Method 4: AC Voltage and Current

For iron-cored coils such as contactor coils, chokes and transformer windings, measure them as they are used. Apply a known AC voltage at a known frequency, measure the current, and measure the DC resistance separately. The Iowa manual gives impedance as Z = √(R² + X²). So:

XL = √((V ÷ I)² − R²)   and   L = XL ÷ (2πf)
Safety: Mains-voltage tests are dangerous. Use a current-limited, isolated or low-voltage supply where you can, and follow your lockout/tagout procedure before connecting to any installed equipment.

Inductance Calculator

Inductance Calculator: Three Methods
1. Resonance with a known capacitor
2. RL time constant
3. AC voltage and current
IndustrialBasics estimate. Assumes a linear coil well below its self-resonant frequency. Iron-cored coils change with current, so test near the operating current.

The default values show three ways of reaching a similar answer: a coil resonating at about 5,033 Hz with 0.1 µF is about 10 mH, and a 100 µs time constant with 100 Ω total resistance is also 10 mH.

Worked Example: Contactor Coil

StepValue
Applied voltage12 V rms at 60 Hz
Measured current0.2 A rms
Impedance12 ÷ 0.2 = 60 Ω
DC resistance20 Ω
Reactance√(60² − 20²) = 56.6 Ω
Inductance56.6 ÷ (2π × 60) = 150 mH
Illustrative readings at a reduced voltage. Inductance at full rated voltage will differ because of the iron core.

A contactor coil’s inductance also rises when its armature closes the magnetic gap, which is why AC coils draw high current while pulling in. See contactor vs relay for how coils are rated, and relay snubber diodes for dealing with the energy stored in DC coils.

Common Mistakes

  • Testing at the wrong frequency. A 1 kHz LCR reading of an iron-cored 60 Hz choke can be very different from its value in service.
  • Ignoring winding resistance. It adds to the loop resistance in the time constant method and to impedance in the AC method.
  • Working near or above the SRF. The reading becomes meaningless above it.
  • Metal near the coil. Eddy currents change the reading.
  • Forgetting DC bias. A power inductor’s value at full load current can be much lower than at zero current.

Coils are also at the heart of inductive proximity sensors, covered in types of industrial sensors. To check a coil’s insulation rather than its inductance, use an insulation resistance test.

Frequently Asked Questions

How do you measure inductance?

Use an LCR meter set to the coil’s working frequency. Without one, measure the resonant frequency with a known capacitor, the RL time constant on an oscilloscope, or the AC voltage and current at a known frequency, and calculate L.

Can a multimeter measure inductance?

Most standard multimeters cannot. Some meters have an inductance range, and dedicated LCR meters measure it directly at set test frequencies.

What is the formula for inductance from resonance?

f = 1 ÷ (2π√(LC)), as in the University of Iowa lab manual. Rearranged: L = 1 ÷ (4π²f²C).

How do I measure inductance with an oscilloscope?

Apply a square wave through a known resistor, measure the time constant τ of the current rise or decay, and use L = τ × R, where R is the total loop resistance including the coil’s own resistance.

Why does my inductor read differently on two meters?

Keysight explains that cored inductors depend on test signal current, and instruments with different source resistance push different currents even at the same voltage setting. Nearby metal also changes readings through eddy currents.

Should I use series or parallel mode on an LCR meter?

Keysight says a series L–Rs model is a good approximation when the inductor has low reactance. High-impedance parts suit the parallel model.

Does DC current change inductance?

Yes, for cored inductors. Keysight notes inductance varies with DC bias current because of the core’s magnetic saturation.

How do I measure the inductance of a motor or contactor coil?

Use the AC method or an LCR meter at the supply frequency. Remember iron-cored coils change with current, and a contactor coil changes when its armature closes.

Sources and Further Reading

About the author

editor